INSTALLATION

CometDaemon Settings

CometDaemon manages connections between Uptivity software modules and other services (such as Service Manager). There is one CometDaemon per server. The actual name of the service is CC Comet Daemon.

The CometDaemon Settings page allows you to view many CometDaemon and Service Manager settings in the NICE Uptivity Web Portal. These settings are typically configured during installation and should only be changed by or under the direction of Uptivity Support.

This topic explains these settings. For more information, see Services Overview.

CometDaemon Web Portal Settings

If the Uptivity system has more than one server node, this page includes CometDaemon and Service Manager settings sections for each. These sections can be toggled open and closed for ease of viewing.

Field

Description

HTTP Port Specifies the port on which the HTTP Server will listen for communication from the Service Manager. The default value is 6505.
HTTP Address Specifies the IP address of the server hosting this CometDaemon. If the server is assigned multiple IP addresses, this field can be used to restrict access to only one of those addresses. The default value is 0.0.0.0, which uses all IP addresses for the server.
HTTP Session Timeout Minutes Specifies in minutes the amount of time before a session times out if CometDaemon receives no messages from the Service Manager. The default value is 10.
Allowed Subnets Client Specifies subnets from which client requests are accepted. The default value is 255.255.255.255/0.
Allowed Subnets System Specifies subnets from which system requests are accepted. In single-server configurations, set this to the IP address of the server. In multi-server configurations, on the server hosting the NICE Uptivity Web Portal, set this to the subnet/IP of the server; on all other servers, leave the setting at the default value of 127.0.0.1/32.
Allowed Subnets Session Specifies subnets from which session key requests are accepted. In multi-server configurations, this should be the IP/subnet of the server hosting the NICE Uptivity Web Portal. For example, assume that Uptivity modules are installed on two machines (Server A and Server B), but the NICE Uptivity Web Portal is installed on only one of the machines (Server A). The CometDaemon for Server B would need the IP address for Server A. For single-server installations, set this to the server IP address/32 (for example, 192.168.0.32/32). The default value is 127.0.0.1/32.

Service Manager Web Portal Settings

Field

Description

Site IP Displays the IP address or hostname for the current server, depending on the Server Node configuration . The default value is 127.0.0.1.
Authorization Port Specifies the port used by the Service Manager. This setting should never be changed and does not appear in the NICE Uptivity Web Portal. The default value is 1024.
Status Timer Interval Specifies the "heartbeat" interval in milliseconds. The default value is 3000 (three seconds).
Configuration Timer Interval Specifies in milliseconds the frequency at which the Service Manager reloads its settings. The default value is 60000 (60 seconds).
Search Directory Specifies the directory location of the Uptivity installation. The default value is C:\Program Files (x86)\CallCopy. Change this value if software was installed in a different directory.